How to Change the Date in Siemens Hipath 4000

How to Change the Date in Siemens Hipath 4000 IP EPBX

To display the date

# DIS-DATE;
H500:  AMO DATE  STARTED
                         +-----------------------------+                      
                         | TUESDAY                     |                      
                         | DATE:            TIME :     |                      
                         | 2011-03-31       14:30:05   |                      
                         |                             |                      
                         | NUMBER OF DAY :   90        |                      
                         | NORMAL TIME                 |                      
                         | GMTDIR: EAST  TIMEOFFS:330  |                      
                         | DSTOFFS:0                   |                      
                         | REL. DIFF. TO GMT :   +330  |                      
                         +-----------------------------+

AMO-DATE -111       TIME AND DATE                                            
DISPLAY COMPLETED;

To change the date

# cha-date
and follow the instructions
To see the options type ?
GMTDIR = ?
GMTDIR          : DIRECTION RELATED TO GMT
CHARACTERISTIC  : REQUIRED                                  
POSS. VALUES : EAST          TIME OFFSET WILL BE ADDED
               WEST          TIME OFFSET WILL BE SUBTRACTED
               UTC           TIME OFFSET WILL BE IGNORED
GMTDIR = utc
TIMEOFFS = ?
TIMEOFFS        : TIME OFFSET IN MINUTES
CHARACTERISTIC  : REQUIRED                                   
POSSIBLE VALUES : 0-1440
TIMEOFFS = 